e-fuse range min~max range is 16~76. if e-fuse value is out of
this range, then thermal sensor may not sense thermal data properly.

CC: Bartlomiej Zolnierkiewicz <b.zolnier...@samsung.com>
Signed-off-by: Anand Moon <linux.am...@gmail.com>
---
 drivers/thermal/samsung/exynos_tmu.c | 10 ++++++----
 1 file changed, 6 insertions(+), 4 deletions(-)

diff --git a/drivers/thermal/samsung/exynos_tmu.c 
b/drivers/thermal/samsung/exynos_tmu.c
index 4a2733c..6481d91 100644
--- a/drivers/thermal/samsung/exynos_tmu.c
+++ b/drivers/thermal/samsung/exynos_tmu.c
@@ -940,11 +940,13 @@ static int exynos_map_dt_data(struct platform_device 
*pdev)
                data->reference_voltage = 16;
                data->efuse_value = 55;
                if (data->soc != SOC_ARCH_EXYNOS5420 &&
-                   data->soc != SOC_ARCH_EXYNOS5420_TRIMINFO)
+                   data->soc != SOC_ARCH_EXYNOS5420_TRIMINFO) {
+                       data->min_efuse_value = 16;
+                       data->max_efuse_value = 76;
+               } else {
                        data->min_efuse_value = 40;
-               else
-                       data->min_efuse_value = 0;
-               data->max_efuse_value = 100;
+                       data->max_efuse_value = 100;
+               }
                break;
        case SOC_ARCH_EXYNOS5433:
                data->tmu_set_trip_temp = exynos5433_tmu_set_trip_temp;
-- 
2.7.4