On Fri, Aug 03, 2018 at 02:08:14PM +0300, Matti Vaittinen wrote:
> ROHM BD71837 PMIC MFD driver providing interrupts and support
> for three subsystems:
> - clk
> - Regulators
> - input/power-key
> 
> Signed-off-by: Matti Vaittinen <[email protected]>
> Reviewed-by: Enric Balletbo i Serra <[email protected]>

I maintained Enric's Reviewed-by as only change I did to v12 was:

> +     ret = regmap_irq_get_virq(bd71837->irq_data, BD71837_INT_PWRBTN_S);
> +
> +     if (ret < 0) {
> +             dev_err(&i2c->dev, "Failed to get the IRQ\n");
> +             return ret;
> +     }
> +
> +     button.irq = ret;

instead of v11 which was:

+       button.irq = regmap_irq_get_virq(bd71837->irq_data,
+                                         BD71837_INT_PWRBTN_S);
+
+       if (button.irq < 0) {
+               dev_err(&i2c->dev, "Failed to get the IRQ\n");
+               return button.irq;
+       }

Br,
        Matti Vaittinen