When testing bind/unbind on r8a7791/koelsch:

    WARNING: CPU: 1 PID: 697 at lib/debugobjects.c:329 
debug_print_object+0x8c/0xb4
    ODEBUG: free active (active state 0) object type: timer_list hint: 
delayed_work_timer_fn+0x0/0x10

This happens if the workqueue runs after the device has been unbound.
Fix this by cancelling any queued work during remove.

Fixes: e0a5172e9eec7f0d ("thermal: rcar: add interrupt support")
Signed-off-by: Geert Uytterhoeven <[email protected]>
---
 drivers/thermal/rcar_thermal.c | 1 +
 1 file changed, 1 insertion(+)

diff --git a/drivers/thermal/rcar_thermal.c b/drivers/thermal/rcar_thermal.c
index ea132e122b174757..616ba2fccf410d3b 100644
--- a/drivers/thermal/rcar_thermal.c
+++ b/drivers/thermal/rcar_thermal.c
@@ -453,6 +453,7 @@ static int rcar_thermal_remove(struct platform_device *pdev)
 
        rcar_thermal_for_each_priv(priv, common) {
                rcar_thermal_irq_disable(priv);
+               cancel_delayed_work_sync(&priv->work);
                if (priv->chip->use_of_thermal)
                        thermal_remove_hwmon_sysfs(priv->zone);
                else
-- 
2.17.1