On 15/11/2018 14:32, Linus Walleij wrote:
> Demote the DBx500 PRCMU clocksource to quality 100 and
> mark it as NONSTOP so it will still be used for
> timekeeping across suspend/resume.
> 
> The Nomadik MTU timer which has higher precision will
> be used when the system is up and running, thanks to
> the recent changes properly utilizing the suspend
> clocksources.
> 
> This was discussed back in 2011 when the driver was
> written, but the infrastructure was not available
> upstream to use this timer properly. Now the
> infrastructure is there, so let's finalize the work.
> 
> Cc: Baolin Wang <[email protected]>
> Signed-off-by: Linus Walleij <[email protected]>
> ---

Both applied, thanks!


-- 
 <http://www.linaro.org/> Linaro.org │ Open source software for ARM SoCs

Follow Linaro:  <http://www.facebook.com/pages/Linaro> Facebook |
<http://twitter.com/#!/linaroorg> Twitter |
<http://www.linaro.org/linaro-blog/> Blog