According to Devicetree specification, the unit-address must match the
first address specified in the reg property of the node.  Fix the DTC
warning onenand node:

    arch/arm/boot/dts/s5pv210.dtsi:81.29-93.5:
        Warning (simple_bus_reg): /soc/onenand@b0000000: simple-bus unit 
address format error, expected "b0600000"

Signed-off-by: Krzysztof Kozlowski <[email protected]>

---

The remaining warning is wrong clock-controller subnode of fimc camera.
    arch/arm/boot/dts/s5pv210.dtsi:578.32-580.6: Warning (simple_bus_reg): 
/soc/camera/clock-controller: missing or empty reg/ranges property
The subnode in my understanding does not follow bindings and the driver.
The driver with current s5pv210.dtsi will not register a clock provider... but
I do not have a device to confirm this.
---
 arch/arm/boot/dts/s5pv210.dtsi | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/arch/arm/boot/dts/s5pv210.dtsi b/arch/arm/boot/dts/s5pv210.dtsi
index cc22c9db80d2..26ea5c66d8ce 100644
--- a/arch/arm/boot/dts/s5pv210.dtsi
+++ b/arch/arm/boot/dts/s5pv210.dtsi
@@ -78,7 +78,7 @@
                        };
                };
 
-               onenand: onenand@b0000000 {
+               onenand: onenand@b0600000 {
                        compatible = "samsung,s5pv210-onenand";
                        reg = <0xb0600000 0x2000>,
                                <0xb0000000 0x20000>,
-- 
2.7.4