On Thu, 2019-02-07 at 10:44 -0800, [email protected] 
wrote:
> From: Kuppuswamy Sathyanarayanan <[email protected]>
> 
> Intel IOMMU Page Request Services (PRS) only works with devices which
> supports/uses PASID. So enable PRI only if the device also enables
> PASID support. For more details, Please check the implementation of PRQ
> handler(prq_event_thread()) in intel-svm driver.
> 
> Cc: Jacob Pan <[email protected]>
> Cc: Ashok Raj <[email protected]>
> Signed-off-by: Kuppuswamy Sathyanarayanan 
> <[email protected]>

Hm, that shouldn't be true. PRI and PASID support are orthogonal.

If we get a PRI request without PASID, we should currently report it as
non-serviced which is the right thing to do. We can hook this up to KVM
etc. to actually allow paging of guests with devices attached, *if* the
devices attached to those guests support PRI.

Nothing fundamentally stops us using PRI without PASID support.


Attachment: smime.p7s
Description: S/MIME cryptographic signature