Hi, Rob

Best Regards!
Anson Huang

> -----Original Message-----
> From: Rob Herring [mailto:[email protected]]
> Sent: 2019年3月26日 4:42
> To: Anson Huang <[email protected]>
> Cc: [email protected]; [email protected];
> [email protected]; [email protected]; [email protected];
> [email protected]; [email protected]; [email protected];
> [email protected]; Leonard Crestez <[email protected]>;
> Robin Gong <[email protected]>; [email protected]; linux-
> [email protected]; [email protected]; linux-arm-
> [email protected]; [email protected]; u.kleine-
> [email protected]; dl-linux-imx <[email protected]>
> Subject: Re: [PATCH V9 1/5] dt-bindings: pwm: Add i.MX TPM PWM binding
> 
> On Fri, Mar 22, 2019 at 01:48:05AM +0000, Anson Huang wrote:
> > Add i.MX TPM(Low Power Timer/Pulse Width Modulation Module) PWM
> binding.
> >
> > Signed-off-by: Anson Huang <[email protected]>
> > ---
> > No changes.
> 
> v9? I don't recall seeing any previous versions.

I checked my mailbox, you are in the "to" list in every version. The first 
version's subject is:
[PATCH 1/5] dt-bindings: pwm: Add i.MX TPM PWM binding...

> 
> > ---
> >  .../devicetree/bindings/pwm/imx-tpm-pwm.txt        | 22
> ++++++++++++++++++++++
> >  1 file changed, 22 insertions(+)
> >  create mode 100644
> > Documentation/devicetree/bindings/pwm/imx-tpm-pwm.txt
> >
> > diff --git a/Documentation/devicetree/bindings/pwm/imx-tpm-pwm.txt
> > b/Documentation/devicetree/bindings/pwm/imx-tpm-pwm.txt
> > new file mode 100644
> > index 0000000..94f1ad5
> > --- /dev/null
> > +++ b/Documentation/devicetree/bindings/pwm/imx-tpm-pwm.txt
> > @@ -0,0 +1,22 @@
> > +Freescale i.MX TPM PWM controller
> > +
> > +Required properties:
> > +- compatible : Should be "fsl,imx-tpm".
> 
> Needs to be SoC specific.

OK, will change it to "fsl,imx7ulp-tpm" in next verson.

> 
> > +- reg: Physical base address and length of the controller's registers.
> > +- #pwm-cells: Should be 3. See pwm.txt in this directory for a description
> of the cells format.
> > +- clocks : The clock provided by the SoC to drive the PWM.
> > +- interrupts: The interrupt for the PWM controller.
> > +
> > +Note: The TPM counter and period counter are shared between multiple
> > +channels, so all channels should use same period setting.
> > +
> > +Example:
> > +
> > +pwm0: tpm@40250000 {
> 
> pwm@...

I forgot to update the example in DT binding, sorry for that, will update it 
according to
below dts node:

                 pwm0: pwm@40250000 {

Anson.