The endianness of data returned from the EC depends on the particular EC
version determined at run time. Cast from little/big endian explicitey
in the routine that flips endianness to the native one to make sparse
happy.

Signed-off-by: Lubomir Rintel <[email protected]>
Reported-by: kbuild test robot <[email protected]>
Fixes: 76311b9a3295 ("power: supply: olpc_battery: Add OLPC XO 1.75 support")
---
 drivers/power/supply/olpc_battery.c | 6 +++---
 1 file changed, 3 insertions(+), 3 deletions(-)

diff --git a/drivers/power/supply/olpc_battery.c 
b/drivers/power/supply/olpc_battery.c
index 4ccd242fcf72..066ec9a11153 100644
--- a/drivers/power/supply/olpc_battery.c
+++ b/drivers/power/supply/olpc_battery.c
@@ -326,9 +326,9 @@ static int olpc_bat_get_voltage_max_design(union 
power_supply_propval *val)
 static u16 ecword_to_cpu(struct olpc_battery_data *data, u16 ec_word)
 {
        if (data->little_endian)
-               return le16_to_cpu(ec_word);
+               return le16_to_cpu((__force __le16)ec_word);
        else
-               return be16_to_cpu(ec_word);
+               return be16_to_cpu((__force __be16)ec_word);
 }
 
 /*********************************************************************
@@ -340,7 +340,7 @@ static int olpc_bat_get_property(struct power_supply *psy,
 {
        struct olpc_battery_data *data = power_supply_get_drvdata(psy);
        int ret = 0;
-       __be16 ec_word;
+       u16 ec_word;
        uint8_t ec_byte;
        __be64 ser_buf;
 
-- 
2.21.0