If CONFIG_FUNCTION_GRAPH_TRACER is enabled function
arch_counter_get_cntvct() is marked as notrace. However, function
__arch_counter_get_cntvct is marked as inline. If
CONFIG_OPTIMIZE_INLINING is set that will make the two functions
tracable which they shouldn't.

Rework so that functions __arch_counter_get_* are marked with
__always_inline so they will be inlined even if CONFIG_OPTIMIZE_INLINING
is turned on.

Fixes: 0ea415390cd3 ("clocksource/arm_arch_timer: Use arch_timer_read_counter 
to access stable counters")
Signed-off-by: Anders Roxell <anders.rox...@linaro.org>
---
 arch/arm64/include/asm/arch_timer.h | 8 ++++----
 1 file changed, 4 insertions(+), 4 deletions(-)

diff --git a/arch/arm64/include/asm/arch_timer.h 
b/arch/arm64/include/asm/arch_timer.h
index b7bca1ae09e6..50b3ab7ded4f 100644
--- a/arch/arm64/include/asm/arch_timer.h
+++ b/arch/arm64/include/asm/arch_timer.h
@@ -193,7 +193,7 @@ static inline void arch_timer_set_cntkctl(u32 cntkctl)
        : "=r" (tmp) : "r" (_val));                                     \
 } while (0)
 
-static inline u64 __arch_counter_get_cntpct_stable(void)
+static __always_inline u64 __arch_counter_get_cntpct_stable(void)
 {
        u64 cnt;
 
@@ -203,7 +203,7 @@ static inline u64 __arch_counter_get_cntpct_stable(void)
        return cnt;
 }
 
-static inline u64 __arch_counter_get_cntpct(void)
+static __always_inline u64 __arch_counter_get_cntpct(void)
 {
        u64 cnt;
 
@@ -213,7 +213,7 @@ static inline u64 __arch_counter_get_cntpct(void)
        return cnt;
 }
 
-static inline u64 __arch_counter_get_cntvct_stable(void)
+static __always_inline u64 __arch_counter_get_cntvct_stable(void)
 {
        u64 cnt;
 
@@ -223,7 +223,7 @@ static inline u64 __arch_counter_get_cntvct_stable(void)
        return cnt;
 }
 
-static inline u64 __arch_counter_get_cntvct(void)
+static __always_inline u64 __arch_counter_get_cntvct(void)
 {
        u64 cnt;
 
-- 
2.20.1

Reply via email to