On 23/07/2019 15.40, Andrew Lunn wrote: > On Mon, Jul 22, 2019 at 11:37:26PM +0000, Rasmus Villemoes wrote: >> We have an ERPS (Ethernet Ring Protection Switching) setup involving >> mv88e6250 switches which we're in the process of switching to a BSP >> based on the mainline driver. Breaking any link in the ring works as >> expected, with the ring reconfiguring itself quickly and traffic >> continuing with almost no noticable drops. However, when plugging back >> the cable, we see 5+ second stalls. > > Hi Rasmus > > I would prefer Vivien reviews this patch. But he is away at the > moment. Are you O.K. to wait a few days?
Sure, no rush. Rasmus