From: Guenter Roeck <[email protected]>
commit ed08ebb7124e90a99420bb913d602907d377d03d upstream.
Holger Hoffstätte observed that Samsung 850 Pro may return invalid
temperatures for a short period of time after resume. Return -ENODATA
to userspace if this is observed.
Fixes: 5b46903d8bf3 ("hwmon: Driver for disk and solid state drives with
temperature sensors")
Reported-by: Holger Hoffstätte <[email protected]>
Cc: Holger Hoffstätte <[email protected]>
Signed-off-by: Guenter Roeck <[email protected]>
Signed-off-by: Greg Kroah-Hartman <[email protected]>
---
drivers/hwmon/drivetemp.c | 6 ++++++
1 file changed, 6 insertions(+)
--- a/drivers/hwmon/drivetemp.c
+++ b/drivers/hwmon/drivetemp.c
@@ -264,12 +264,18 @@ static int drivetemp_get_scttemp(struct
return err;
switch (attr) {
case hwmon_temp_input:
+ if (!temp_is_valid(buf[SCT_STATUS_TEMP]))
+ return -ENODATA;
*val = temp_from_sct(buf[SCT_STATUS_TEMP]);
break;
case hwmon_temp_lowest:
+ if (!temp_is_valid(buf[SCT_STATUS_TEMP_LOWEST]))
+ return -ENODATA;
*val = temp_from_sct(buf[SCT_STATUS_TEMP_LOWEST]);
break;
case hwmon_temp_highest:
+ if (!temp_is_valid(buf[SCT_STATUS_TEMP_HIGHEST]))
+ return -ENODATA;
*val = temp_from_sct(buf[SCT_STATUS_TEMP_HIGHEST]);
break;
default: