pm_runtime_get_sync() increments the runtime PM usage counter even
when it returns an error code. Thus a pairing decrement is needed on
the error handling path to keep the counter balanced.

Signed-off-by: Dinghao Liu <[email protected]>
---

Changelog:

v2: - Use pm_runtime_put_noidle() instead of pm_runtime_put().
---
 drivers/spi/spi-tegra20-slink.c | 1 +
 1 file changed, 1 insertion(+)

diff --git a/drivers/spi/spi-tegra20-slink.c b/drivers/spi/spi-tegra20-slink.c
index 7f4d932dade7..a07b72e9c344 100644
--- a/drivers/spi/spi-tegra20-slink.c
+++ b/drivers/spi/spi-tegra20-slink.c
@@ -1118,6 +1118,7 @@ static int tegra_slink_probe(struct platform_device *pdev)
        ret = pm_runtime_get_sync(&pdev->dev);
        if (ret < 0) {
                dev_err(&pdev->dev, "pm runtime get failed, e = %d\n", ret);
+               pm_runtime_put_noidle(&pdev->dev);
                goto exit_pm_disable;
        }
        tspi->def_command_reg  = SLINK_M_S;
-- 
2.17.1