On Thu, 21 May 2020 17:06:15 +0800, Weiyi Lu wrote:
> Add power dt-bindings of MT8183 and introduces "BASIC" and
> "SUBSYS" clock types in binding document.
> The "BASIC" type is compatible to the original power control with
> clock name [a-z]+[0-9]*, e.g. mm, vpu1.
> The "SUBSYS" type is used for bus protection control with clock
> name [a-z]+-[0-9]+, e.g. isp-0, cam-1.
> And add an optional "mediatek,smi" property for phandle to smi-common
> node.
> 
> Signed-off-by: Weiyi Lu <[email protected]>
> ---
>  .../devicetree/bindings/soc/mediatek/scpsys.txt    | 21 ++++++++++++++---
>  include/dt-bindings/power/mt8183-power.h           | 26 
> ++++++++++++++++++++++
>  2 files changed, 44 insertions(+), 3 deletions(-)
>  create mode 100644 include/dt-bindings/power/mt8183-power.h
> 

Reviewed-by: Rob Herring <[email protected]>

Reply via email to