commit b5a84ecf025a ("mmc: tegra: Add Tegra210 support")

Tegra210 and later uses separate SDMMC_LEGACY_TM clock for data
timeout.

So, this patch adds "tmclk" to Tegra sdhci clock property in the
device tree binding.

Fixes: b5a84ecf025a ("mmc: tegra: Add Tegra210 support")
Cc: stable <[email protected]> # 4.19
Reviewed-by: Jon Hunter <[email protected]>
Signed-off-by: Sowjanya Komatineni <[email protected]>
---
 .../bindings/mmc/nvidia,tegra20-sdhci.txt          | 23 ++++++++++++++++++++--
 1 file changed, 21 insertions(+), 2 deletions(-)

diff --git a/Documentation/devicetree/bindings/mmc/nvidia,tegra20-sdhci.txt 
b/Documentation/devicetree/bindings/mmc/nvidia,tegra20-sdhci.txt
index 9bce578..a5f1fae 100644
--- a/Documentation/devicetree/bindings/mmc/nvidia,tegra20-sdhci.txt
+++ b/Documentation/devicetree/bindings/mmc/nvidia,tegra20-sdhci.txt
@@ -14,8 +14,15 @@ Required properties:
   - "nvidia,tegra124-sdhci": for Tegra124 and Tegra132
   - "nvidia,tegra210-sdhci": for Tegra210
   - "nvidia,tegra186-sdhci": for Tegra186
-- clocks : Must contain one entry, for the module clock.
-  See ../clocks/clock-bindings.txt for details.
+- clocks: For Tegra210 and Tegra186 must contain two entries.
+         One for the module clock and one for the timeout clock.
+         For all other Tegra devices, must contain a single entry for
+         the module clock. See ../clocks/clock-bindings.txt for details.
+- clock-names: For Tegra210 and Tegra186 must contain the strings 'sdhci'
+              and 'tmclk' to represent the module and the timeout clocks,
+              respectively.
+              For all other Tegra devices must contain the string 'sdhci'
+              to represent the module clock.
 - resets : Must contain an entry for each entry in reset-names.
   See ../reset/reset.txt for details.
 - reset-names : Must include the following entries:
@@ -38,3 +45,15 @@ sdhci@c8000200 {
        power-gpios = <&gpio 155 0>; /* gpio PT3 */
        bus-width = <8>;
 };
+
+sdhci@700b0000 {
+       compatible = "nvidia,tegra210-sdhci";
+       reg = <0x0 0x700b0000 0x0 0x200>;
+       interrupts = <GIC_SPI 14 IRQ_TYPE_LEVEL_HIGH>;
+       clocks = <&tegra_car TEGRA210_CLK_SDMMC1>,
+                <&tegra_car TEGRA210_CLK_SDMMC_LEGACY>;
+       clock-names = "sdhci", "tmclk";
+       resets = <&tegra_car 14>;
+       reset-names = "sdhci";
+       status = "disabled";
+};
-- 
2.7.4