On 1/8/2021 7:29 PM, Peter Geis wrote:
External email: Use caution opening links or attachments


Current implementation defaults the hda clocks to clk_m. This causes hda
to run too slow to operate correctly. Fix this by defaulting to pll_p and
setting the frequency to the correct rate.

This matches upstream t124 and downstream t30.

Acked-by: Jon Hunter <[email protected]>
Tested-by: Ion Agorria <[email protected]>
Signed-off-by: Peter Geis <[email protected]>
---
  drivers/clk/tegra/clk-tegra30.c | 2 ++
  1 file changed, 2 insertions(+)

Acked-by: Sameer Pujar <[email protected]>

Reply via email to