Hello Clemens,

On Tue, Dec 15, 2020 at 10:22:25PM +0100, Clemens Gruber wrote:
> Reset the prescale and ON/OFF registers to their POR default state in
> the probe function. Otherwise, the PWMs could still be active after a
> watchdog reset and reboot, etc.

My memories are swapped out because it's already so long ago I looked
into this series. I thought it was already said that taking over the
configured state in probe is the nice thing to do?!

Best regards
Uwe

-- 
Pengutronix e.K.                           | Uwe Kleine-König            |
Industrial Linux Solutions                 | https://www.pengutronix.de/ |

Attachment: signature.asc
Description: PGP signature