On Mon, Apr 05, 2021 at 07:50:00AM -0300, Luiz Sampaio wrote:
> The following patches aim to make a user able to calibrate the current 
> measurement of the DS2438. This chip uses a offset register in page1, which 
> is added to the current register to give the user the current measurement. If 
> this value is wrong, the user will get an offset current value, even if the 
> current is zero, for instance. This patch gives support for reading the page1 
> registers (including the offset register) and for writing to the offset 
> register. The DS2438 datasheet shows a calibration routine, and with this 
> patch, the user can do this quickly by writing the correct value to the 
> offset register. This patch was tested on real hardware using a power supply 
> and an electronic load.
> Please help to review this series of patches.

Please linewrap your text here :(