Hi,

On Wed, Apr 07, 2021 at 01:15:11PM +0200, Krzysztof Kozlowski wrote:
> On 07/04/2021 11:19, Yang Yingliang wrote:
> > This driver's remove path calls cancel_delayed_work(). However, that
> > function does not wait until the work function finishes. This means
> > that the callback function may still be running after the driver's
> > remove function has finished, which would result in a use-after-free.
> > 
> > Fix by calling cancel_delayed_work_sync(), which ensures that
> > the work is properly cancelled, no longer running, and unable
> > to re-schedule itself.
> > 
> > Reported-by: Hulk Robot <hul...@huawei.com>
> > Signed-off-by: Yang Yingliang <yangyingli...@huawei.com>
> > ---
> >  drivers/power/supply/s3c_adc_battery.c | 2 +-
> >  1 file changed, 1 insertion(+), 1 deletion(-)
> > 
> 
> Reviewed-by: Krzysztof Kozlowski <krzysztof.kozlow...@canonical.com>

Thanks,

queued.

-- Sebastian

Attachment: signature.asc
Description: PGP signature

Reply via email to