On 4/19/21 11:38 AM, gabriel.fernan...@foss.st.com wrote:
From: Gabriel Fernandez <gabriel.fernan...@foss.st.com>

Introduce new compatible string "st,stm32mp1-rcc-secure" for
stm32mp1 clock driver when the device is configured with RCC
security support hardened.

Signed-off-by: Etienne Carriere <etienne.carri...@foss.st.com>
Signed-off-by: Gabriel Fernandez <gabriel.fernan...@foss.st.com>
---
  .../devicetree/bindings/clock/st,stm32mp1-rcc.yaml          | 6 ++++--
  1 file changed, 4 insertions(+), 2 deletions(-)

diff --git a/Documentation/devicetree/bindings/clock/st,stm32mp1-rcc.yaml 
b/Documentation/devicetree/bindings/clock/st,stm32mp1-rcc.yaml
index 4e385508f516..8b1ecb2ecdd5 100644
--- a/Documentation/devicetree/bindings/clock/st,stm32mp1-rcc.yaml
+++ b/Documentation/devicetree/bindings/clock/st,stm32mp1-rcc.yaml
@@ -54,7 +54,9 @@ properties:
compatible:
      items:
-      - const: st,stm32mp1-rcc
+      - enum:
+          - st,stm32mp1-rcc-secure
+          - st,stm32mp1-rcc

It is still the same IP and same SoC silicon, so shouldn't the configuration be discerned via DT property instead of compatible string ?