Dear Wim,

Am Mittwoch, den 30.01.2013, 20:19 +0100 schrieb Wim Van Sebroeck:

> > In case of SB800 or later chipset and re-programming MMIO address(*),
> > sp5100_tco module may read incorrect value of reserved bit, because the 
> > module
> > reads a value from an incorrect I/O address. However, this bug doesn't cause
> > a problem, because when re-programming MMIO address, by chance the module
> > writes zero (this is BIOS's default value) to the low three bits of 
> > register.
> > * In most cases, PC with SB8x0 or later chipset doesn't need to 
> > re-programming
> >   MMIO address, because such PC can enable AcpiMmio and can use 0xfed80b00 
> > for
> >   watchdog register base address.
> > 
> > This patch fixes this bug.
> > 
> > Bugzilla: https://bugzilla.kernel.org/show_bug.cgi?id=43176
> > Signed-off-by: Takahisa Tanaka <[email protected]>
> 
> Added to linux-watchdog-next.

Is it allowed to rewrite history of linux-watchdog-next? If yes, could
you please add `CC: [email protected]` to both of Takahisa’s
patches and also add my

    Tested-by: Paul Menzel <[email protected]>
        ASRock E350M1 (SB800)

as commented on the bug report to it?


Thanks,

Paul

Attachment: signature.asc
Description: This is a digitally signed message part

Reply via email to