linux-os wrote:
On Tue, 1 Mar 2005, Ben Greear wrote:

I supplied the actual settings.

What happens if you just don't muck with the NIC and let it auto-negotiate
on it's own?



It goes to half-duplex and runs 9 to 9.5 megabytes/second as stated above.

That's why I think 1/2 duplex is __really__ full-duplex.

half-duplex will run near line speed in one direction. Try sending in both directions at the same time and you'll get closer to 40% of the link utilization... Also, if you see any collisions you are in half-duplex mode.

You could try connecting the NICs back-to-back with a cross-over
cable to take your switch out of the loop?

Ben


-- Ben Greear <[EMAIL PROTECTED]> Candela Technologies Inc http://www.candelatech.com

-
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to [EMAIL PROTECTED]
More majordomo info at  http://vger.kernel.org/majordomo-info.html
Please read the FAQ at  http://www.tux.org/lkml/

Reply via email to