Hello Alan

>
> What is the locking between setting/getting/driver use of the config ?
> This really needs a lock (termios sem I think is perhaps appropriate
> given when the values are normally referenced).

I tried implementing it with the sermios sem
((&(uart_port)->state->port.tty->termios_rwsem)), but some drivers
access the rs485 structure inside their irq handler. So I have see
options here

1) Protect the structure with uart_port->lock spinlock
2) Assume that an assignment is atomic on critical sections where I
cannot hold the rwsem.

I think 1) is more correct. Any issues that I continue in this
direction? Any better idea?


Thanks!

-- 
Ricardo Ribalda
--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majord...@vger.kernel.org
More majordomo info at  http://vger.kernel.org/majordomo-info.html
Please read the FAQ at  http://www.tux.org/lkml/