From: const <co...@ctera.com> Excerpt from datasheet: 7.2.32 Mode Selection Register RTD3_MD : 00=Closed , 01=Reserved , 10=Thermistor mode , 11=Voltage sense
Show temp3 only in Thermistor mode Signed-off-by: Constantine Shulyupin <co...@makelinux.com> --- drivers/hwmon/nct7802.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/drivers/hwmon/nct7802.c b/drivers/hwmon/nct7802.c index 5418417..dcca5fc 100644 --- a/drivers/hwmon/nct7802.c +++ b/drivers/hwmon/nct7802.c @@ -649,7 +649,7 @@ static umode_t nct7802_temp_is_visible(struct kobject *kobj, if (index >= 9 && index < 18 && (reg & 0x0c) != 0x04 && (reg & 0x0c) != 0x08) /* RD2 */ return 0; - if (index >= 18 && index < 27 && (reg & 0x30) != 0x10) /* RD3 */ + if (index >= 18 && index < 27 && (reg & 0x30) != 0x20) /* RD3 */ return 0; if (index >= 27 && index < 35) /* local */ return attr->mode; -- 1.9.1 -- To unsubscribe from this list: send the line "unsubscribe linux-kernel" in the body of a message to majord...@vger.kernel.org More majordomo info at http://vger.kernel.org/majordomo-info.html Please read the FAQ at http://www.tux.org/lkml/