GCC 13.2.0 compiler issued the following warning:

mixer-test.c:350:80: warning: format ‘%ld’ expects argument of type ‘long int’, 
\
                              but argument 5 has type ‘unsigned int’ [-Wformat=]
  350 |                         ksft_print_msg("%s.%d value %ld more than item 
count %ld\n",
      |                                                                         
     ~~^
      |                                                                         
       |
      |                                                                         
       long int
      |                                                                         
     %d
  351 |                                        ctl->name, index, int_val,
  352 |                                        
snd_ctl_elem_info_get_items(ctl->info));
      |                                        
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
      |                                        |
      |                                        unsigned int

Fixing the format specifier in call to ksft_print_msg() according to the
compiler suggestion silences the warning.

Fixes: 10f2f194663af ("kselftest: alsa: Validate values read from enumerations")
Cc: Mark Brown <[email protected]>
Cc: Jaroslav Kysela <[email protected]>
Cc: Takashi Iwai <[email protected]>
Cc: Shuah Khan <[email protected]>
Cc: [email protected]
Cc: [email protected]
Cc: [email protected]
Signed-off-by: Mirsad Todorovac <[email protected]>
---
 tools/testing/selftests/alsa/mixer-test.c | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/tools/testing/selftests/alsa/mixer-test.c 
b/tools/testing/selftests/alsa/mixer-test.c
index df942149c6f6..e3708cc52db7 100644
--- a/tools/testing/selftests/alsa/mixer-test.c
+++ b/tools/testing/selftests/alsa/mixer-test.c
@@ -347,7 +347,7 @@ static bool ctl_value_index_valid(struct ctl_data *ctl,
                }
 
                if (int_val >= snd_ctl_elem_info_get_items(ctl->info)) {
-                       ksft_print_msg("%s.%d value %ld more than item count 
%ld\n",
+                       ksft_print_msg("%s.%d value %ld more than item count 
%d\n",
                                       ctl->name, index, int_val,
                                       snd_ctl_elem_info_get_items(ctl->info));
                        return false;
-- 
2.40.1