Any feedback on this? On Wednesday 05 June 2013 13:42:39, Alexander Stein wrote: > When the signal stack frame is created, it must be flushed in order to > make sure the cache fetches the correct data. > Without cache flush the icache might pick up old cached data from an older > signal stack frame if the signal is raised again very fast. > In case of copyback the data cache muist be pushed first, but is untested. > > Signed-off-by: Alexander Stein <[email protected]> > --- > arch/m68k/kernel/signal.c | 8 ++++++++ > 1 file changed, 8 insertions(+) > > diff --git a/arch/m68k/kernel/signal.c b/arch/m68k/kernel/signal.c > index 2a16df3..57fd286 100644 > --- a/arch/m68k/kernel/signal.c > +++ b/arch/m68k/kernel/signal.c > @@ -50,6 +50,7 @@ > #include <asm/pgtable.h> > #include <asm/traps.h> > #include <asm/ucontext.h> > +#include <asm/cacheflush.h> > > #ifdef CONFIG_MMU > > @@ -181,6 +182,13 @@ static inline void push_cache (unsigned long vaddr) > asm volatile ("movec %0,%%caar\n\t" > "movec %1,%%cacr" > : : "r" (vaddr + 4), "r" (temp)); > + } else { > + /* CPU_IS_COLDFIRE */ > +#if defined(CONFIG_CACHE_COPYBACK) > + flush_cf_dcache(0, DCACHE_MAX_ADDR); > +#endif > + /* Invalidate instruction cache for the pushed bytes */ > + clear_cf_icache(vaddr, vaddr + 8); > } > } > > -- Dipl.-Inf. Alexander Stein
SYS TEC electronic GmbH Am Windrad 2 08468 Heinsdorfergrund Tel.: 03765 38600-1156 Fax: 03765 38600-4100 Email: [email protected] Website: www.systec-electronic.com Managing Director: Dipl.-Phys. Siegmar Schmidt Commercial registry: Amtsgericht Chemnitz, HRB 28082 -- To unsubscribe from this list: send the line "unsubscribe linux-m68k" in the body of a message to [email protected] More majordomo info at http://vger.kernel.org/majordomo-info.html