Hi Hans,

Texas Instruments Finland Oy, Porkkalankatu 22, 00180 Helsinki. 
Y-tunnus/Business ID: 0615521-4. Kotipaikka/Domicile: Helsinki

On 11/08/17 13:57, Tomi Valkeinen wrote:

> I'm doing some testing with this series on my panda. One issue I see is
> that when I unload the display modules, I get:
> 
> [   75.180206] platform 58006000.encoder: enabled after unload, idling
> [   75.187896] platform 58001000.dispc: enabled after unload, idling
> [   75.198242] platform 58000000.dss: enabled after unload, idling

This one is caused by hdmi_cec_adap_enable() never getting called with
enable=false when unloading the modules. Should that be called
explicitly in hdmi4_cec_uninit, or is the CEC framework supposed to call it?

 Tomi

Reply via email to