wlpeake wrote:

> Trying to agetty to answer data line and when line rings something
> prints to the screen:
> 
> INIT: Id "d2" respawning too fast, disabled for 5 minutes
> 2.0.34 Slackware 3.5 (Lots of newbie changes to files)

`respawning too fast' means that a program which is run via inittab
using the `respawn' option is terminating immediately. The log files
may provide some clues as to why.

You might wish to use a different getty (e.g. uugetty, mgetty) for
handling modem lines; agetty isn't particularly configurable.

-- 
Glynn Clements <[EMAIL PROTECTED]>
-
To unsubscribe from this list: send the line "unsubscribe linux-net" in
the body of a message to [EMAIL PROTECTED]

Reply via email to