Off mode is now using the omap2 retention fix code for scanning GPIOs
only during off-mode transitions. All the *non_wakeup_gpios variables
are now used for off-mode transition tracking on OMAP3. This patch fixes
cases where GPIO state changes are missed during off-mode.
Signed-off-by: Tero Kristo <[EMAIL PROTECTED]>
---
arch/arm/mach-omap2/pm34xx.c | 10 ++++++----
arch/arm/plat-omap/gpio.c | 18 ++++++++++++++++--
2 files changed, 22 insertions(+), 6 deletions(-)
diff --git a/arch/arm/mach-omap2/pm34xx.c b/arch/arm/mach-omap2/pm34xx.c
index 5723240..2aaa631 100644
--- a/arch/arm/mach-omap2/pm34xx.c
+++ b/arch/arm/mach-omap2/pm34xx.c
@@ -321,9 +321,10 @@ void omap_sram_idle(void)
per_next_state = pwrdm_read_next_pwrst(per_pwrdm);
if (per_next_state < PWRDM_POWER_ON) {
omap_uart_prepare_idle(2);
- omap2_gpio_prepare_for_retention();
- if (per_next_state == PWRDM_POWER_OFF)
+ if (per_next_state == PWRDM_POWER_OFF) {
+ omap2_gpio_prepare_for_retention();
omap3_per_save_context();
+ }
}
/* CORE */
@@ -396,9 +397,10 @@ void omap_sram_idle(void)
/* PER */
if (per_next_state < PWRDM_POWER_ON) {
per_prev_state = pwrdm_read_prev_pwrst(per_pwrdm);
- if (per_prev_state == PWRDM_POWER_OFF)
+ if (per_prev_state == PWRDM_POWER_OFF) {
omap3_per_restore_context();
- omap2_gpio_resume_after_retention();
+ omap2_gpio_resume_after_retention();
+ }
omap_uart_resume_idle(2);
}
diff --git a/arch/arm/plat-omap/gpio.c b/arch/arm/plat-omap/gpio.c
index 62349fd..b45bf9d 100644
--- a/arch/arm/plat-omap/gpio.c
+++ b/arch/arm/plat-omap/gpio.c
@@ -556,7 +556,9 @@ static inline void set_24xx_gpio_triggering(struct
gpio_bank *bank, int gpio,
else
__raw_writel(1 << gpio, bank->base
+ OMAP24XX_GPIO_CLEARWKUENA);
+#ifdef CONFIG_ARCH_OMAP24XX
} else {
+#endif
if (trigger != 0)
bank->enabled_non_wakeup_gpios |= gpio_bit;
else
@@ -1485,9 +1487,11 @@ static int __init _omap_gpio_init(void)
#if defined(CONFIG_ARCH_OMAP24XX) || defined(CONFIG_ARCH_OMAP34XX)
if (bank->method == METHOD_GPIO_24XX) {
+#ifdef CONFIG_ARCH_OMAP24XX
static const u32 non_wakeup_gpios[] = {
0xe203ffc0, 0x08700040
};
+#endif
__raw_writel(0x00000000, bank->base +
OMAP24XX_GPIO_IRQENABLE1);
__raw_writel(0xffffffff, bank->base +
OMAP24XX_GPIO_IRQSTATUS1);
@@ -1495,8 +1499,10 @@ static int __init _omap_gpio_init(void)
/* Initialize interface clock ungated, module enabled */
__raw_writel(0, bank->base + OMAP24XX_GPIO_CTRL);
+#ifdef CONFIG_ARCH_OMAP24XX
if (i < ARRAY_SIZE(non_wakeup_gpios))
bank->non_wakeup_gpios = non_wakeup_gpios[i];
+#endif
gpio_count = 32;
}
#endif
@@ -1666,7 +1672,11 @@ void omap2_gpio_prepare_for_retention(void)
/* Remove triggering for all non-wakeup GPIOs. Otherwise spurious
* IRQs will be generated. See OMAP2420 Errata item 1.101. */
+#ifdef CONFIG_ARCH_OMAP24XX
for (i = 0; i < gpio_bank_count; i++) {
+#else
+ for (i = 1; i < gpio_bank_count; i++) {
+#endif
struct gpio_bank *bank = &gpio_bank[i];
u32 l1, l2;
@@ -1681,7 +1691,7 @@ void omap2_gpio_prepare_for_retention(void)
bank->saved_risingdetect = l2;
l1 &= ~bank->enabled_non_wakeup_gpios;
l2 &= ~bank->enabled_non_wakeup_gpios;
-#if defined(CONFIG_ARCH_OMAP24XX) || defined(CONFIG_ARCH_OMAP34XX)
+#if defined(CONFIG_ARCH_OMAP24XX)
__raw_writel(l1, bank->base + OMAP24XX_GPIO_FALLINGDETECT);
__raw_writel(l2, bank->base + OMAP24XX_GPIO_RISINGDETECT);
#endif
@@ -1700,7 +1710,11 @@ void omap2_gpio_resume_after_retention(void)
if (!workaround_enabled)
return;
+#ifdef CONFIG_ARCH_OMAP24XX
for (i = 0; i < gpio_bank_count; i++) {
+#else
+ for (i = 1; i < gpio_bank_count; i++) {
+#endif
struct gpio_bank *bank = &gpio_bank[i];
u32 l;
@@ -1720,7 +1734,7 @@ void omap2_gpio_resume_after_retention(void)
l = __raw_readl(bank->base + OMAP24XX_GPIO_DATAIN);
#endif
l ^= bank->saved_datain;
- l &= bank->non_wakeup_gpios;
+ l &= bank->enabled_non_wakeup_gpios;
if (l) {
u32 old0, old1;
#if defined(CONFIG_ARCH_OMAP24XX) || defined(CONFIG_ARCH_OMAP34XX)
--
1.5.4.3
--
To unsubscribe from this list: send the line "unsubscribe linux-omap" in
the body of a message to [EMAIL PROTECTED]
More majordomo info at http://vger.kernel.org/majordomo-info.html