Add regulator-name properties for the regulators that don't have them,
allowing the kernel to display the name from the schematic rather than
the name of the regulator on the PMIC in order to improve diagnostics.

Signed-off-by: Mark Brown <broo...@kernel.org>
---
 arch/arm/boot/dts/am335x-bone-common.dtsi | 5 +++++
 1 file changed, 5 insertions(+)

diff --git a/arch/arm/boot/dts/am335x-bone-common.dtsi 
b/arch/arm/boot/dts/am335x-bone-common.dtsi
index bde1777b62be..fe983d204b2b 100644
--- a/arch/arm/boot/dts/am335x-bone-common.dtsi
+++ b/arch/arm/boot/dts/am335x-bone-common.dtsi
@@ -227,6 +227,7 @@
 &tps {
        regulators {
                dcdc1_reg: regulator@0 {
+                       regulator-name = "vdds_dpr";
                        regulator-always-on;
                };
 
@@ -249,18 +250,22 @@
                };
 
                ldo1_reg: regulator@3 {
+                       regulator-name = "vio,vrtc,vdds";
                        regulator-always-on;
                };
 
                ldo2_reg: regulator@4 {
+                       regulator-name = "vdd_3v3aux";
                        regulator-always-on;
                };
 
                ldo3_reg: regulator@5 {
+                       regulator-name = "vdd_1v8";
                        regulator-always-on;
                };
 
                ldo4_reg: regulator@6 {
+                       regulator-name = "vdd_3v3a";
                        regulator-always-on;
                };
        };
-- 
2.1.0

--
To unsubscribe from this list: send the line "unsubscribe linux-omap" in
the body of a message to majord...@vger.kernel.org
More majordomo info at  http://vger.kernel.org/majordomo-info.html

Reply via email to