Nishanth Menon <[email protected]> writes:

[...]

>
> Does the following sound any better?:

Yes, thanks.

> Blindly setting a 1.2v setting in the initial structure may not even
> match the default voltages stored in the voltage table which are
> supported for the domain. For example, OMAP3430 core domain does not
> use 1.2v and ends up generating a warning on the first transition.
>
> Further, since omap2_set_init_voltage is called as part of the pm
> framework's initialization sequence to configure the voltage required
> for the current OPP, the call does(and has to) setup the system
> voltage(curr_volt as a result) using the right mechanisms appropriate
> for the system at that point of time. This also overrides
> initialization we are currently doing in voltage.c  making it
> redundant. So remove the wrong and useless initialization.
--