On Fri, Feb 24, 2012 at 04:25:12PM +0200, Tero Kristo wrote:

> Still, setting selector in this case does nothing, as it is immediately
> overwritten by the regulator core by -1. This looks like a perfectly
> acceptable way to implement a regulator, as everything checks for the
> presence of list_voltage anyway.

Ah, so it is - we're fixing things up in the core.  I'd forgotten we did
that.