Hi,

On Fri, 2012-03-23 at 13:48 +0100, Jan Weitzel wrote:
> Add displays to panel-generic-dpi.c
> Prime View PD050VL1 (640 x 480)
> Prime View PD104SLF (800 x 600)
> Prime View PM070WL4 (800 x 480)
> 
> Signed-off-by: Jan Weitzel <[email protected]>
> ---
>  drivers/video/omap2/displays/panel-generic-dpi.c |   63 
> ++++++++++++++++++++++
>  1 files changed, 63 insertions(+), 0 deletions(-)
> 
> diff --git a/drivers/video/omap2/displays/panel-generic-dpi.c 
> b/drivers/video/omap2/displays/panel-generic-dpi.c
> index 28b9a6d..85ee8d3 100644
> --- a/drivers/video/omap2/displays/panel-generic-dpi.c
> +++ b/drivers/video/omap2/displays/panel-generic-dpi.c
> @@ -363,6 +363,69 @@ static struct panel_config generic_dpi_panels[] = {
>  
>               .name                   = "ortustech_com43h4m10xtc",
>       },
> +
> +     /* Prime-View PD050VL1 */
> +     {
> +             {
> +                     .x_res          = 640,
> +                     .y_res          = 480,
> +
> +                     .pixel_clock    = 25000,
> +
> +                     .hsw            = 96,
> +                     .hfp            = 18,
> +                     .hbp            = 46,
> +
> +                     .vsw            = 2,
> +                     .vfp            = 10,
> +                     .vbp            = 33,
> +             },
> +             .config                 = OMAP_DSS_LCD_TFT | OMAP_DSS_LCD_IVS |
> +                                       OMAP_DSS_LCD_IHS | OMAP_DSS_LCD_IPC,
> +             .name                   = "pd050vl1",
> +     },

Please use a company name prefix in the name field like the other panels
do, so we avoid any possible name conflicts.

 Tomi


Attachment: signature.asc