On Mon, Aug 20, 2012 at 06:27:01AM +0000, AnilKumar, Chimata wrote:
> On Thu, Aug 16, 2012 at 19:30:56, Mark Brown wrote:

> > Why does this mean you need multiple regulators?  A single regulator can
> > of course supply multiple devices.

> I got your point but tps65910 driver is failing if we add single fixed
> regulator. Solution is driver needs to change or add multiple fixed
> regulators.

No, really.  One regulator can supply many things, not being a.

> vrtc:
> tps65910 0-002d: Failed to find supply vcc7
> tps65910 0-002d: failed to register tps65910-pmic regulator

So you've specified a whole bunch of supplies and this one individual
supply is not matching (and it's not the first...).  You should
investigate what's gone wrong there rather than bodging around the
problem.  I can't immediately say anything much based on the information
you've given.

Attachment: signature.asc
Description: Digital signature

Reply via email to