On Thursday 25 October 2012 05:55 PM, Felipe Balbi wrote:
In case we loop on IRQ handler until stat is
finally zero, we would end up in a situation
where all I2C transfers would misteriously
timeout because we were not calling complete()
in that situation.
Fix the issue by moving omap_i2c_complete_cmd()
call inside the 'out' label.
Signed-off-by: Felipe Balbi <[email protected]>
---
Looks fine. Have you hit this issue in any corner case ?
Regards
santosh
--
To unsubscribe from this list: send the line "unsubscribe linux-omap" in
the body of a message to [email protected]
More majordomo info at http://vger.kernel.org/majordomo-info.html