On Wednesday 18 September 2013 07:20 AM, Sricharan R wrote: > The real time counter also called master counter, is a free-running > counter. It produces the count used by the CPU local timer peripherals > in the MPU cluster. The timer counts at a rate of 6.144 MHz. > > The ratio registers are missing for a sys-clk of 20MHZ which is used > by DRA7 socs. So because of this, the counter was getting wrongly > programmed for a sys-clk of 38.4Mhz(default). So adding the ratio > registers for 20MHZ sys-clk. > > Cc: Santosh Shilimkar <[email protected]> > Signed-off-by: Sricharan R <[email protected]> > --- Acked-by: Santosh Shilimkar <[email protected]>
-- To unsubscribe from this list: send the line "unsubscribe linux-omap" in the body of a message to [email protected] More majordomo info at http://vger.kernel.org/majordomo-info.html