On Thu, 01 Apr 2010, mcclnx mcc wrote: > We have DELL R900 with two MD1000 connect to it. Recently I found following > messages continue pop-up on /var/log/messages file. I used DELL OPMN to > check and NO error. Anyone know why? > > ======================================================= > Mar 31 10:11:37 ORA6 Server Administrator: Storage Service EventID: 2095 > SCSI sense data Sense key: 5 Sense code: 24 Sense qualifier: 0: Enclosure > 0:0 Controller 0, Connector 0 > Mar 31 10:11:37 ORA6 Server Administrator: Storage Service EventID: 2095 > SCSI sense data Sense key: 5 Sense code: 24 Sense qualifier: 0: Enclosure > 1:0 Controller 0, Connector 1 > Mar 31 10:11:38 ORA6 Server Administrator: Storage Service EventID: 2095 > SCSI sense data Sense key: 5 Sense code: 24 Sense qualifier: 0: Enclosure > 0:0 Controller 2, Connector 0 > > Mar 31 13:12:37 ORA6 Server Administrator: Storage Service EventID: 2095 > SCSI sense data Sense key: 5 Sense code: 24 Sense qualifier: 0: Enclosure > 0:0 Controller 0, Connector 0 > Mar 31 13:12:37 ORA6 Server Administrator: Storage Service EventID: 2095 > SCSI sense data Sense key: 5 Sense code: 24 Sense qualifier: 0: Enclosure > 1:0 Controller 0, Connector 1 > Mar 31 13:12:37 ORA6 Server Administrator: Storage Service EventID: 2095 > SCSI sense data Sense key: 5 Sense code: 24 Sense qualifier: 0: Enclosure > 0:0 Controller 2, Connector 0 > For a couple of weeks in March I had EvenID 2095 on one of my drive (Dell drive in a MD1000). Then the drive failed, and the messages went away once it was replaced. This is one example of the messages I was getting:
Mar 23 03:27:41 ccrm3 Server Administrator: Storage Service EventID: 2095 SCSI sense data Sense key: B Sense code: 4B Sense qualifier: 3: Physical Disk 1:0:1 Controller 1, Connector 1 A similar scenarios occured in an another MD1000 just after Christmas: a few days of messages, then a failed disk: Dec 27 21:06:02 climate Server Administrator: Storage Service EventID: 2095 SCSI sense data Sense key: 6 Sense code: 29 Sense qualifier: 0: Physical Disk 0:0:10 Controller 1, Connector 0 Dec 27 21:06:03 climate Server Administrator: Storage Service EventID: 2095 SCSI sense data Sense key: 5 Sense code: 24 Sense qualifier: 0: Physical Disk 0:0:10 Controller 1, Connector 0 Dec 27 21:06:03 climate Server Administrator: Storage Service EventID: 2095 SCSI sense data Sense key: 5 Sense code: 24 Sense qualifier: 0: Physical Disk 0:0:10 Controller 1, Connector 0 So my past experience based on these 2 data points is that 2095 messages are a sign of a disk failure coming sooner than later... Daniel -- Daniel Robitaille _______________________________________________ Linux-PowerEdge mailing list [email protected] https://lists.us.dell.com/mailman/listinfo/linux-poweredge Please read the FAQ at http://lists.us.dell.com/faq