No, there is no way to clear these errors out.

These errors include lots of things like "Unexpected SENSE" conditions coming 
from the drives. Are they health concerns? Probably not, but it is possible 
that some of them are.

From: linux-poweredge-bounces-Lists On Behalf Of Jacob Perkins
Sent: Monday, May 10, 2010 9:35 AM
Cc: linux-poweredge-Lists
Subject: Re: MegaCLI 'Other Errors Count'

Is there a way to clear these other errors out?

It looks like alot of errors that are being thrown are the 6/29/00 (POWER ON, 
RESET, OR BUS DEVICE RESET OCCURRED), which seem to conincide with reboots or 
kernel panics on our systems, and instead of holding onto this error, is there 
a way to just get rid of it?

Looking through the MegaCLI interface, there doesn't seem to be a way to, and 
Google doesn't turn up anything either.

Thanks in advance.

On 5/7/2010 4:05 PM, [email protected]<mailto:[email protected]> 
wrote:

-----Original Message-----

From: linux-poweredge-bounces-Lists On Behalf Of Jacob Perkins

Sent: Friday, May 07, 2010 11:32 AM

To: linux-poweredge-Lists

Subject: MegaCLI 'Other Errors Count'



Hello all!

I'm hoping someone might be able to point me in the right direction.

We're running RAID 10 on MegaRAID LSI cards and I'm seeing an 'Other

Error Count' being reported via MegaCLI.  What are these?  Should I

consider these health concerns?



Enclosure Device ID: 32

Slot Number: 0

Device Id: 0

Sequence Number: 2

Media Error Count: 0

Other Error Count: 9

Predictive Failure Count: 0

Last Predictive Failure Event Seq Number: 0

Raw Size: 715404MB [0x575466f0 Sectors]

Non Coerced Size: 714892MB [0x574466f0 Sectors]

Coerced Size: 714880MB [0x57440000 Sectors]

Firmware state: Online

SAS Address(0): 0x1221000000000000

Connected Port Number: 0(path0)

Inquiry Data: ATA     ST3750330NS     SN06            9QK25R6K





Thanks!



-----Original Message-----



Hi,



Other errors can be anything other than a bad block like SCSI bus communication 
errors.  I would make sure my firmware is up to date on the hard drives and the 
PERC controller.



Here's a list of common error codes



http://en.wikipedia.org/wiki/Key_Code_Qualifier







Ben Gordy

Enterprise Technical Support Senior Analyst

Dell | Enterprise Solutions - Platinum

Office (toll free) 1-800-945-3355 x946 4848

[email protected]<mailto:[email protected]>







--

Thanks!



Jacob Perkins

Level II Linux Systems Administrator

Systems Monitoring



HostGator.com LLC

http://support.hostgator.com



            .-._   _ _ _ _ _ _ _ _

 .-''-.__.-'00  '-' ' ' ' ' ' ' ' '-.

'.___ '    .   .--_'-' '-' '-' _'-' '._

 V: V 'vv-'   '_   '.       .'  _..' '.'.

   '=.____.=_.--'   :_.__.__:_   '.   : :

           (((____.-'        '-.  /   : :

                             (((-'\ .' /

                           _____..'  .'

                          '-._____.-'
_______________________________________________
Linux-PowerEdge mailing list
[email protected]
https://lists.us.dell.com/mailman/listinfo/linux-poweredge
Please read the FAQ at http://lists.us.dell.com/faq

Reply via email to