it helps half:

/etc/rc.d/init.d/dsm_om_connsvc start
Starting DSM SA Connection Service:                        [  OK  ]


/etc/rc.d/init.d/dsm_om_shrsvc start
Starting DSM SA Shared Services: terminate called after throwing an
instance of 'DellSupport::DellException'
/bin/bash: line 1:  5560
Aborted                 /opt/dell/srvadmin/sbin/dsm_om_shrsvcd
                                                           [FAILED]


tnx anyway.. 1 more step to go.. ;-)

regards,

Arno

Op dinsdag 25-05-2010 om 14:48 uur [tijdzone -0500], schreef Eric
Rostetter:
> Quoting "Support @ Technologist.si" <[email protected]>:
> 
> > Executing /etc/rc.d/init.d/dsm_om_shrsvc start ..
> >
> > Starting DSM SA Shared Services: terminate called after throwing an  
> > instance of 'std::runtime_error'
> >   what():  locale::facet::_S_create_c_locale name not valid
> > /bin/bash: line 1: 27610 Terminated               
> > /opt/dell/srvadmin/sbin/dsm_om_shrsvcd
> > [FAILED]
> 
> See if typing:
> 
> export LC_ALL="C"
> 
> before you start it fixes it...  It fixed a problem for me on one of my
> systems (an rpath linux install).  Not seen it elsewhere (CentOS/RHEL
> installs).
> 


_______________________________________________
Linux-PowerEdge mailing list
[email protected]
https://lists.us.dell.com/mailman/listinfo/linux-poweredge
Please read the FAQ at http://lists.us.dell.com/faq