it helps half:
/etc/rc.d/init.d/dsm_om_connsvc start
Starting DSM SA Connection Service: [ OK ]
/etc/rc.d/init.d/dsm_om_shrsvc start
Starting DSM SA Shared Services: terminate called after throwing an
instance of 'DellSupport::DellException'
/bin/bash: line 1: 5560
Aborted /opt/dell/srvadmin/sbin/dsm_om_shrsvcd
[FAILED]
tnx anyway.. 1 more step to go.. ;-)
regards,
Arno
Op dinsdag 25-05-2010 om 14:48 uur [tijdzone -0500], schreef Eric
Rostetter:
> Quoting "Support @ Technologist.si" <[email protected]>:
>
> > Executing /etc/rc.d/init.d/dsm_om_shrsvc start ..
> >
> > Starting DSM SA Shared Services: terminate called after throwing an
> > instance of 'std::runtime_error'
> > what(): locale::facet::_S_create_c_locale name not valid
> > /bin/bash: line 1: 27610 Terminated
> > /opt/dell/srvadmin/sbin/dsm_om_shrsvcd
> > [FAILED]
>
> See if typing:
>
> export LC_ALL="C"
>
> before you start it fixes it... It fixed a problem for me on one of my
> systems (an rpath linux install). Not seen it elsewhere (CentOS/RHEL
> installs).
>
_______________________________________________
Linux-PowerEdge mailing list
[email protected]
https://lists.us.dell.com/mailman/listinfo/linux-poweredge
Please read the FAQ at http://lists.us.dell.com/faq