FYI, you can see the MIB info at: http://www.oidview.com/mibs/674/MIB-Dell-10892.html
Shawn -----Original Message----- From: [email protected] [mailto:[email protected]] On Behalf Of [email protected] Sent: Thursday, June 10, 2010 4:55 AM To: [email protected]; [email protected]; [email protected] Subject: RE: various temperature for PowerEdge R710 Adding Rajesh from FW engineering. -----Original Message----- From: [email protected] [mailto:[email protected]] On Behalf Of John G. Heim Sent: Wednesday, June 09, 2010 7:57 PM To: linux-poweredge-Lists Subject: Re: various temperature for PowerEdge R710 When I want specific temps, I use snmpget. Of course, then you have the problem of figuring out which OID corresponds to which temp. And I do not know that myself. I found some of them via google. For example, the OID for chassis temp is 1.3.6.1.4.1.674.10892.1.700.20.1.6.1.1. So to display the chassis temp, you should be able to say: snmpget -v2c -c public localhost 1.3.6.1.4.1.674.10892.1.700.20.1.6.1.1 Maybe somebody on this list knows how to match an OID with a Dell hardware sensor. I do not. The only way I know is to figure it out from various examples of snmpget you can find by googling. ----- Original Message ----- From: "Zhichao Li" <[email protected]> To: "Tim Small" <[email protected]> Cc: <[email protected]> Sent: Tuesday, June 08, 2010 8:13 PM Subject: Re: various temperature for PowerEdge R710 > Thanks Tim. > > And I just don't understand why Dell give the same name "Temp" for > all kinds of temperature sensors. I mean, how can I tell which one is > for which temperature sensors? > > Could someone give me some ideas about that? > > Thanks, > Zhichao > > On Tue, Jun 8, 2010 at 11:33 AM, Tim Small <[email protected]> wrote: > >> Zhichao Li wrote: >> > especially the first Temp, I mean it's weired the value is less than >> > zero. >> > >> >> That's likely to be the CPU thermal margin - i.e. it's not an absolute >> temperature, but is relative to the upper limit set by the CPU. I'm not >> really sure why the BMC reports it like this, possibly that's just all >> the information that the CPU makes available. >> >> It shows up using "ipmitool sdr list", but not "ipmitool sensor list" - >> without checking, I assume the second method is asking for an absolute >> temperature (which comes back as "na" on this PE R300). >> >> >> Tim. >> > > > > -- > Zhichao Li > Computer Science Department > Stony Brook University > ------------------------------------------------------------------------ -------- > _______________________________________________ > Linux-PowerEdge mailing list > [email protected] > https://lists.us.dell.com/mailman/listinfo/linux-poweredge > Please read the FAQ at http://lists.us.dell.com/faq _______________________________________________ Linux-PowerEdge mailing list [email protected] https://lists.us.dell.com/mailman/listinfo/linux-poweredge Please read the FAQ at http://lists.us.dell.com/faq _______________________________________________ Linux-PowerEdge mailing list [email protected] https://lists.us.dell.com/mailman/listinfo/linux-poweredge Please read the FAQ at http://lists.us.dell.com/faq _______________________________________________ Linux-PowerEdge mailing list [email protected] https://lists.us.dell.com/mailman/listinfo/linux-poweredge Please read the FAQ at http://lists.us.dell.com/faq