DTK tool racadm can reset DRAC configuration to factory default values.
Command line is - racadm racresetcfg.
To Enable serial over lan you can choose either of the commands given
below-
syscfg solcfgparams --solenable=enable
racadm config -g cfgipmisol -o cfgipmisolenable 1
Hope this answers your question.
----
Vibha
On Thu, May 20, 2010 at 1:01 PM, Jefferson Ogata
<[email protected]> wrote:
> 2. In BMC setup (control-E during POST), enable serial over LAN, set
IP
> and password.
>
> ** First thing you should do in BMC setup is reset to default. The
BMCs
> often ship with a weird non-default setting that will cause lots of
> serial port feedback if you try to run a getty on the serial console.
Is it possible to do this step in an automated fashion? i.e. without
using the Manual Ctrl+E?
Would ipmitool, or syscfg or another equivalent tool have the way of
setting the BMC SOL? I already set the BMC's IP and pasword using
ipmitool.
I have ~300 machines so doing this step manually via Ctrl+E is tedious.
--
Rahul
_______________________________________________
Linux-PowerEdge mailing list
[email protected]
https://lists.us.dell.com/mailman/listinfo/linux-poweredge
Please read the FAQ at http://lists.us.dell.com/faq