On 15/10/10 20:53, Drew Weaver wrote:
We don't want the management NIC or traffic to be visible to the operating system for security reasons.
It won't be - the OS never sees traffic destined for the BMC, it goes directly from the NIC chip to the BMC, and doesn't hit the PCIe bus which is attached to the main computer, so it's pretty much invisible (and it'd be encrypted anyway, and you can enforce encrypted-only coms). The BMC gets its own MAC and IP address (these days, older IPMI implementations did it differently).
I use IPMI and SoL exclusive - don't bother with the DRACs - don't need them (and you can't get them on Tyans or Intels or HPs, whereas I can use ipmitool on everything).
If you're looking for low cost, did you consider the R210s? Tim. -- South East Open Source Solutions Limited Registered in England and Wales with company number 06134732. Registered Office: 2 Powell Gardens, Redhill, Surrey, RH1 1TQ VAT number: 900 6633 53 http://seoss.co.uk/ +44-(0)1273-808309
_______________________________________________ Linux-PowerEdge mailing list [email protected] https://lists.us.dell.com/mailman/listinfo/linux-poweredge Please read the FAQ at http://lists.us.dell.com/faq