Hi, > > Raphael Mazelier wrote: > > Hello list, > > The interface is still up from both the server and the switch side, > but > > traffic (I think incoming traffic) is dropped (rx_discard counter > growing). > > > > My settup is classic : lenny, standard (2.6.26) or bpo (2.6.32) > kernel, > > dellomsa 6. > > > > Hi, > > I saw something similar today on an R300, on a Debian/Lenny box, when > doing heavy IPMI/SoL work. ip link set eth0 down ; ip link set eth0 up > fixed things. > > Tim. >
Did not fix things for me. Server is still not reachable. Module unload/load fixes things, yes, but I don't think that this is an option when build into kernel. I also get a segfault from dsm_sa_datamgrd in libdcadpt.so when started when module tg3 is loaded. But its still running with another process id. Starting dsm_sa_datamgrd with unloaded tg3 and and loading tg3 afterwards works. Regards, Sebastian _______________________________________________ Linux-PowerEdge mailing list [email protected] https://lists.us.dell.com/mailman/listinfo/linux-poweredge Please read the FAQ at http://lists.us.dell.com/faq