On Nov 15, 2010, at 9:09 AM, J. Epperson wrote:

> On Thu, November 11, 2010 10:25, Jacob P wrote:
>> Hello,
>> 
>> I'm having an issue with a PERC 6/i card and I was hoping to get some
>> guidance from the gurus on this list.
>> 
>> We're having an issue with the controller 'puncturing bad blocks', but
>> it's 'remembering' the sectors after swapping out with a hotspare.
>> 
> 
> Looks like the infamous and somewhat nebulous "punctured stripe".  Your
> PERC is presenting the RAID volume as an emulated hard disk, and when you
> end up with emulated bad blocks, they'll move around WRT the actual
> physical drives.  The only sure way to get rid of them is said to be
> recreating the volume from scratch and reloading the files from backup.
> 
> There are people participating on this list who understand this far better
> than I do, and I hope one or more of them elaborate for us.


This was a memorable one, hope it helps:

http://lists.us.dell.com/pipermail/linux-poweredge/2010-May/042140.html