In fact usb_storage module is loaded at boot but dsu failed to upgrade iDRAC. Don't understand why ?
Le 22/03/2016 05:03, [email protected] a écrit : > Dell - Internal Use - Confidential > Thanks for sharing the screenshot. > > The USB interface is used to update iDRAC firmware so the usb_storage driver > should be enabled and loaded to update the iDRAC firmware on the system. The > console message are displayed by operating system to show USB connection > status. Please ignore these message as they do not affect the system > > Thanks > Santosh > > From: linux-poweredge-bounces-Lists On Behalf Of Jean-Daniel TISSOT > Sent: Monday, March 21, 2016 8:55 PM > To: Gottloeb, Jeff (ES & CSO) <[email protected]>; > linux-poweredge-Lists <[email protected]> > Subject: Re: [Linux-PowerEdge] EXT : R720 DSU and iDRAC version > > No, I change settings to have usb-storage module loaded at boot time and I > get the same result. > On the console, I have these messages about sdab (the virtual device) > > [cid:[email protected]] > Le 21/03/2016 15:18, Gottloeb, Jeff (ES & CSO) a écrit : > Do you have the usb-storage kernel module disabled or uninstalled? DSU (and > OMSA) up to v8.3 require this kernel module. Found this out after a couple > of weeks of troubleshooting with Dell. > > Sent from my Windows Phone > ________________________________ > From: Jean-Daniel TISSOT<mailto:[email protected]> > Sent: 3/21/2016 5:44 AM > To: [email protected]<mailto:[email protected]> > Subject: EXT :[Linux-PowerEdge] R720 DSU and iDRAC version > > Hi, > > This server is running CentOS release 6.7 > > dsu --apply-upgrades-only show me a new version (2.30.30.30) for iDRAC with > Lifecycle Controller (2.21.21.21 installed). > Booting on Lyfecycle and searching for new firmwares don't find anything to > upgrade. > Searching on Dell Support web site for my Service Tag found only 2.21.21.21 > version of iDrac. > > Runining dsu -u give me : > > |-----------Dell System Updates-----------| > [ ] represents 'not selected' > [*] represents 'selected' > [-] represents 'Component already at repository version (can be selected only > if -e option is used)' > Choose: q - Quit without update, c to Commit, <number> - To Select/Deselect, > a - Select All, n - Select None > > [*]1 iDRAC > Current Version : 2.21.21.21 Upgrade to : 2.30.30.30 > > Enter your choice : c > Installing iDRAC-with-Lifecycle-Controller_Firmware_JHF76_LN_2.30.30.30_A00... > Collecting inventory... > . > Running validation... > > iDRAC > > The version of this Update Package is newer than the currently installed > version. > Software application name: iDRAC > Package version: 2.30.30.30 > Installed version: 2.21.21.21 > > > Executing update... > WARNING: DO NOT STOP THIS PROCESS OR INSTALL OTHER DELL PRODUCTS WHILE UPDATE > IS IN PROGRESS. > THESE ACTIONS MAY CAUSE YOUR SYSTEM TO BECOME UNSTABLE! > ......................................................................... > USB Device is not found > ................................................................... USB > Device is not found > .................................................................. USB > Device is not found > ......................... > Device: iDRAC > Application: iDRAC > Failed to access Virtual USB Device > > iDRAC-with-Lifecycle-Controller_Firmware_JHF76_LN_2.30.30.30_A00 could not be > installed > > > Why the virtual device disconnect several time ? How to correct this problem ? > > Many thanks in advance. > > Cheers. > > -- > Bien cordialement, Jean-Daniel > TISSOT<http://chrono-environnement.univ-fcomte.fr/spip.php?article457> > Administrateur Systèmes et Réseaux > Tel: +33 3 81 666 440 Fax: +33 3 81 666 568 > > Laboratoire Chrono-environnement<http://chrono-environnement.univ-fcomte.fr/> > 16, Route de Gray > 25030 BESANÇON Cédex > > Plan et > Accès<https://mapsengine.google.com/map/viewer?mid=zjsxW4ZzZPLY.kp2qPHUBD45c> > > -- > Bien cordialement, Jean-Daniel > TISSOT<http://chrono-environnement.univ-fcomte.fr/spip.php?article457> > Administrateur Systèmes et Réseaux > Tel: +33 3 81 666 440 Fax: +33 3 81 666 568 > > Laboratoire Chrono-environnement<http://chrono-environnement.univ-fcomte.fr/> > 16, Route de Gray > 25030 BESANÇON Cédex > > Plan et > Accès<https://mapsengine.google.com/map/viewer?mid=zjsxW4ZzZPLY.kp2qPHUBD45c> -- Bien cordialement, Jean-Daniel TISSOT <http://chrono-environnement.univ-fcomte.fr/spip.php?article457> Administrateur Systèmes et Réseaux Tel: +33 3 81 666 440 Fax: +33 3 81 666 568 Laboratoire Chrono-environnement <http://chrono-environnement.univ-fcomte.fr/> 16, Route de Gray 25030 BESANÇON Cédex Plan et Accès <https://mapsengine.google.com/map/viewer?mid=zjsxW4ZzZPLY.kp2qPHUBD45c>
_______________________________________________ Linux-PowerEdge mailing list [email protected] https://lists.us.dell.com/mailman/listinfo/linux-poweredge