Hi Santosh, It's failed again.
racadm racreset doesn't work [root@chrono-svg ~]# racadm racreset NOTE: The current version of Integrated Dell Remote Access Controller (iDRAC) that do not support the execution of RACADM commands. Contact Dell customer service to upgrade to iDRAC Express or iDRAC Enterprise The installed version of RACADM client executable that do not match the generation of the server. I have an iDRAC 7 enterprise but racadm4 and racadm5 are the only versions installed with OMSA. [root@chrono-svg ~]# omreport about Product name : Dell OpenManage Server Administrator Version : 8.2.0 Copyright : Copyright (C) Dell Inc. 1995-2015 All rights reserved. Company : Dell Inc. OS is CentOS 6.7 (I do : 'touch /opt/dell/srvadmin/lib64/openmanage/IGNORE_GENERATION' for OMSA works) But now dsu don't find iDRAC update, Catalog error ?? [root@chrono-svg ~]# /usr/sbin/dsu --apply-upgrades-only Verifying catalog installation ... Installing catalog from repository ... Verifying inventory collector installation ... Getting System Inventory... Determining Applicable Updates... No Applicable Updates Available Le 23/03/2016 07:47, [email protected] a écrit : > > *Dell - Internal Use - Confidential * > > Hi Henrik, > > > > Please reset the iDRAC using the command “*racadm racreset” *and then update > iDRAC and BIOS components on the system. We will ask team to reproduce issue > in our lab to root cause this issue. > > > > Thanks > > Santosh > > -----Original Message----- > From: linux-poweredge-bounces-Lists On Behalf Of Henrik Schmiediche > Sent: Wednesday, March 23, 2016 12:58 AM > To: linux-poweredge-Lists > Subject: [Linux-PowerEdge] DSU upgrade issue BIOS/iDRAC > > > I have a R620 I am trying to upgrade. When I try, I receive iDRAC and BIOS > updates (see below). The errors appear in Scientific Linux 6.x and Centos 7.2 > - same errors. > > How do I apply the updates? > > dsu --inventory below as well. > > Regards, > - Henrik > > > ------ > > ]# modprobe usb-storage > ]# dsu --non-interactive > Verifying catalog installation ... > Installing catalog from repository ... > Verifying inventory collector installation ... > Getting System Inventory... > Determining Applicable Updates... > Installing > iDRAC-with-Lifecycle-Controller_Firmware_JHF76_LN_2.30.30.30_A00... > Collecting inventory... > ................................ > Running validation... > > iDRAC > > The version of this Update Package is newer than the currently installed > version. > Software application name: iDRAC > Package version: 2.30.30.30 > Installed version: 1.51.51.00 > > Executing update... > WARNING: DO NOT STOP THIS PROCESS OR INSTALL OTHER DELL PRODUCTS WHILE UPDATE > IS IN PROGRESS. > THESE ACTIONS MAY CAUSE YOUR SYSTEM TO BECOME UNSTABLE! > .................................................................................................. > USB Device is not found > .................................................................... USB > Device is not found > .................................................................... USB > Device is not found . > Failed to access Virtual USB Device > > iDRAC > Failed to access Virtual USB Device > Failed to access Virtual USB Device > > iDRAC-with-Lifecycle-Controller_Firmware_JHF76_LN_2.30.30.30_A00 could not be > installed Installing BIOS_KR1XT_LN_2.5.4... > Collecting inventory... > . > Running validation... > > Server BIOS 12G > > The version of this Update Package is newer than the currently installed > version. > Software application name: BIOS > Package version: 2.5.4 > Installed version: 2.1.3 > > Executing update... > WARNING: DO NOT STOP THIS PROCESS OR INSTALL OTHER DELL PRODUCTS WHILE UPDATE > IS IN PROGRESS. > THESE ACTIONS MAY CAUSE YOUR SYSTEM TO BECOME UNSTABLE! > ..................... > Creation of Dynamic Partition Failed. > > BIOS_KR1XT_LN_2.5.4 could not be installed > > Done! Please run 'dsu --inventory' to check the inventory > > ------ > ]# dsu --inventory > Verifying catalog installation ... > Installing catalog from repository ... > Verifying inventory collector installation ... > Getting System Inventory... > > 1. BIOS ( Version : 2.1.3 ) > 2. Power Supply ( Version : 07.2B.7D ) > 3. PERC H710 Mini Controller 0 Firmware ( Version : 21.3.2-0005 ) 4. Firmware > for - Disk 0 in Backplane 1 of PERC H710 Mini Controller > 0 ( Version : LS0B ) > 5. 12G SEP Firmware ( Version : 1.00 ) > 6. iDRAC ( Version : 1.51.51.00 ) > 7. NetXtreme BCM5720 Gigabit Ethernet PCIe (em1) ( Version : 7.10.64 ) 8. > NetXtreme BCM5720 Gigabit Ethernet PCIe (em2) ( Version : 7.10.64 ) 9. > NetXtreme BCM5720 Gigabit Ethernet PCIe (em3) ( Version : 7.10.64 ) 10. > NetXtreme BCM5720 Gigabit Ethernet PCIe (em4) ( Version : 7.10.64 ) > > -- > Henrik Schmiediche, Ph.D. '93 > Director of Information Technology, College of Science Instructional > Associate Professor, Statistics > [email protected] Phone: 979 845-3141 > > _______________________________________________ > Linux-PowerEdge mailing list > [email protected] > https://lists.us.dell.com/mailman/listinfo/linux-poweredge > > > > _______________________________________________ > Linux-PowerEdge mailing list > [email protected] > https://lists.us.dell.com/mailman/listinfo/linux-poweredge -- Bien cordialement, Jean-Daniel TISSOT <http://chrono-environnement.univ-fcomte.fr/spip.php?article457> Administrateur Systèmes et Réseaux Tel: +33 3 81 666 440 Fax: +33 3 81 666 568 Laboratoire Chrono-environnement <http://chrono-environnement.univ-fcomte.fr/> 16, Route de Gray 25030 BESANÇON Cédex Plan et Accès <https://mapsengine.google.com/map/viewer?mid=zjsxW4ZzZPLY.kp2qPHUBD45c>
_______________________________________________ Linux-PowerEdge mailing list [email protected] https://lists.us.dell.com/mailman/listinfo/linux-poweredge
