Hi We tried all these voo-doo's to no avail (each several time for 2-5 min).
We also contacted support (the brick is still under warranty). Support advice was the same (unplug, keep power button or keep reset idrac (i-icon) for 20s). Support gave 2 more hints: (a) clear NVRAM using NVRAM jumper on MB, (b) take off all equipment from a server except CPU #1 , one DIMM, one PSU and system board. Nothing helped. Server does not boot OS, no VGA display, no IP connection to iDRAC, nothing on serial port. The only 2 positives: both PSU have power, disks start flashing after power-on. Support decided to replace MB. Waiting for serviceman ... Grzegorz 2016-04-08 20:30 GMT+02:00 Luke Pyzowski <[email protected]>: > I've had this exact type of issue, and holding the power button as > mentioned below fixed the issue for me. Additionally, I'd recommend pulling > the CMOS battery out if that fails. > > Luke Pyzowski > > > -----Original Message----- > From: [email protected] [mailto: > [email protected]] On Behalf Of Stephen Dowdy > Sent: Friday, April 08, 2016 11:39 AM > To: Grzegorz Bakalarski > Cc: linux-poweredge-Lists > Subject: Re: [Linux-PowerEdge] R720XD dead after IDRAC update trial > > Grzegorz, > > I've had a motherboard replacement needed due to iDRAC updates before. > It's pretty frustrating. > > The only "emergency" procedure you might try: > > - disconnect power cords to PSUs > - press and HOLD the power button to "drain the Flea power" (i presume > this is a capacitor store residuals?) > Hold for 30 seconds > - reconnect PSUs to power > - power on and enable CAPS LOCK, SCROLL LOCK and NUM LOCK (may not be able > to do immediately) > This *MAY* require you get into the BIOS "Setup" menu (<F2>) (which you > indicate seems unlikely) > - Press <ALT><E> , <ALT><F>, <ALT><B> > I can only imagine this stands for "Emergency F*ing Boot" > > If you are lucky, then the system will be reset. If not, you might want > to give up and have the Motherboard replaced (sigh) > > Ref: > > http://en.community.dell.com/techcenter/systems-management/w/wiki/3464.troubleshooting-idrac6-issues > > Good Luck, > --stephen > > > > -- > Stephen Dowdy - Systems Administrator - NCAR/RAL > 303.497.2869 - [email protected] - > http://www.ral.ucar.edu/~sdowdy/ > > _______________________________________________ > Linux-PowerEdge mailing list > [email protected] > https://lists.us.dell.com/mailman/listinfo/linux-poweredge >
_______________________________________________ Linux-PowerEdge mailing list [email protected] https://lists.us.dell.com/mailman/listinfo/linux-poweredge