I think I said before that I do get emails for the results -- but I don't find emails for successful consistency checks useful. I simply have too many emails to go through to have to read every one of them carefully for errors. This is why we have automation!
In any case, I found a couple places where all the possible alerts are defined: http://www.dell.com/support/manuals/us/en/19/dell-opnmang-sw-v8.2/messages-r eference-guide-v3/Event-ID-%E2%80%94-2085?guid=GUID-C2DE4234-02E9-481B-921B- 8F1AE526AD14&lang=en-us Or on a linux server with OMSA installed -- in the HTML files in : /opt/dell/srvadmin/lib64/openmanage/apache-tomcat/webapps/omsa/help/hip/en/m essageguide It looks like the Event ID is the same on both Windows and Linux, so I should be able to use that to filter them. But the forum post I linked earlier is incomplete; there are more failure modes than the 4 listed on that page. I extracted all the text messages and event IDs from the HTML; any error descriptions mentioning "consistency" are below. Event ID - 2058 Virtual disk check consistency started Event ID - 2114 A consistency check on a virtual disk has been paused (suspended) Event ID - 2343 The Check Consistency logging of inconsistent parity data is disabled Event ID - 2397 The Check Consistency completed with uncorrectable errors Event ID - 2076 Virtual disk Check Consistency failed Event ID - 2115 A consistency check on a virtual disk has been resumed Event ID - 2235 The Check Consistency rate has changed Event ID - 2342 The Check Consistency found inconsistent parity data. Data redundancy may be lost Event ID - 2341 The Check Consistency made corrections and completed Event ID - 2192 The virtual disk Check Consistency has made corrections and completed Event ID - 2067 Virtual disk check consistency cancelled Event ID - 2340 The BGI completed with uncorrectable errors Event ID - 2223 Abort Check Consistency on Error, Replace Member Operation and Loadbalance changed Event ID - 2227 Abort Check Consistency on Error, Replace Member Operation and Auto Replace Member Operation on Predictive Failure changed Event ID - 2225 Abort Check Consistency on Error and Load balance changed Event ID - 2219 Abort Check Consistency on Error, Replace Member Operation, Auto Replace Member Operation on Predictive Failure and Loadbalance changed Event ID - 2229 Abort Check Consistency on Error and Auto Replace Member Operation on Predictive Failure changed Event ID - 2237 Abort Check Consistency on Error modified Event ID - 2048 Device failed Event ID - 2085 Virtual disk check consistency completed Event ID - 2231 Replace Member Operation and Abort Check Consistency on Error changed Event ID - 2417 There is an unrecoverable medium error detected on virtual disk Event ID - 2396 The Check Consistency detected uncorrectable multiple medium errors _______________________________________________ Linux-PowerEdge mailing list [email protected] https://lists.us.dell.com/mailman/listinfo/linux-poweredge