Dell - Internal Use - Confidential Davide,
Resetting would have been my next suggestion if the below commands would not have worked. Good to know that it worked. Thank You for choosing Dell Technologies. Regards, Prasanth K S R From: Davide Ferrari [mailto:[email protected]] Sent: Friday, September 30, 2016 1:10 PM To: Ksr, Prasanth <[email protected]> Cc: linux-poweredge-Lists <[email protected]> Subject: Re: [Linux-PowerEdge] Different status report between OMSA and iDRAC Hello again strangely enough, after a power reset via IPMI (the machine became unrensponsive before I can read your emails), OMSA now reports the same status of the iDRAC for that DIMM. Thanks for your answers anyway! 2016-09-30 8:28 GMT+02:00 <[email protected]<mailto:[email protected]>>: Dell - Internal Use - Confidential Davide, Can you please try the below commands and restart the OMSA services: dcicfg command=clearmemfailures dcicfg command=clearthresholds Please let us know in case it solves the issue. Regards, Prasanth K S R _______________________________________________ Linux-PowerEdge mailing list [email protected]<mailto:[email protected]> https://lists.us.dell.com/mailman/listinfo/linux-poweredge -- Davide Ferrari Senior Systems Engineer
_______________________________________________ Linux-PowerEdge mailing list [email protected] https://lists.us.dell.com/mailman/listinfo/linux-poweredge