hi everyone

I'm trying something simple:

$ perccli /c0 add vd raid5 drives=32:0-5 pdcache=on

and it spits back on me:

Controller = 0
Status = Failure
Description = physical disk does not have appropriate attributes

currently:
..
PD LIST :
=======

-----------------------------------------------------------------------------
EID:Slt DID State DG     Size Intf Med SED PI SeSz 
Model                  Sp
-----------------------------------------------------------------------------
32:0      0 JBOD  -  1.818 TB SATA HDD N   N  512B 
ST2000LM003 HN-M201RAD U
32:1      1 JBOD  -  1.818 TB SATA HDD N   N  512B 
ST2000LM003 HN-M201RAD U
32:2      2 JBOD  -  1.818 TB SATA HDD N   N  512B 
ST2000LM003 HN-M201RAD U
32:3      3 JBOD  -  1.818 TB SATA HDD N   N  512B 
ST2000LM003 HN-M201RAD U
32:4      4 JBOD  -  1.818 TB SATA HDD N   N  512B 
ST2000LM003 HN-M201RAD U
32:5      5 JBOD  -  1.818 TB SATA HDD N   N  512B 
ST2000LM003 HN-M201RAD U

would you know why?
many thanks,
L.