Just had this same issue with the latest SUU for R710. Any update on fixing this bug?
Server is out of warranty. Thanks, John On Thu, 8 Jun 2017, sash...@dell.com wrote: > Date: Thu, 8 Jun 2017 07:50:08 +0000 > From: sash...@dell.com > To: linux-powere...@lists.us.dell.com > Subject: Re: [Linux-PowerEdge] Enough contiguous physical memory is not > available to perform the BIOS update running under, this Operating System. > > Hi, > > We've checked with the dependent team regarding the problem you faced and the > suggestion was to reboot the system to release contiguous memory. > However, if you still face the issue after reboot, we advise you to please > get in touch with Dell Technical Support. > > Regards, > Sashi > sash...@dell.com<mailto:sash...@dell.com> > > From: linux-poweredge-bounces-Lists On Behalf Of Malte Schmidt > Sent: Sunday, June 4, 2017 7:43 PM > To: linux-poweredge-Lists > <linux-powere...@lists.us.dell.com<mailto:linux-powere...@lists.us.dell.com>> > Subject: Re: [Linux-PowerEdge] Enough contiguous physical memory is not > available to perform the BIOS update running under, this Operating System. > > > Just a kind reminder that this problem is not solved yet. > > Is there any update on this? > > Best regards > > On 01/18/2017 09:10 PM, Vincent Hoffman-Kazlauskas wrote: > > Just a me too, but I was running dsu from a standard install not a > > liveCD, I rebooted and tried again a few times just in case. > > A centos6 livecd on the same box worked fine. > > > > Vince > > > > On 18/01/2017 18:24, Malte Schmidt wrote: > > Running dsu on CentOS 7 (live, the DSET-iso), i am getting the following > > error even after 3 reboots. > > > > Questions: Is this an known issue? How to fix it? > > > > [*]1 BIOS > > Current Version : 2.2.10 Upgrade to : 6.4.0 > > > > [...] > > > > Enter your choice : c > > Fetching R610_BIOS_C6MRW_LN_6.4.0 ... > > Installing R610_BIOS_C6MRW_LN_6.4.0 ... > > Collecting inventory... > > . > > Running validation... > > > > BIOS > > > > The version of this Update Package is newer than the currently installed > > version. > > Software application name: BIOS > > Package version: 6.4.0 > > Installed version: 2.2.10 > > > > > > Executing update... > > WARNING: DO NOT STOP THIS PROCESS OR INSTALL OTHER DELL PRODUCTS WHILE > > UPDATE IS IN PROGRESS. > > THESE ACTIONS MAY CAUSE YOUR SYSTEM TO BECOME UNSTABLE! > > ............................................. > > Device: BIOS > > Application: BIOS > > Enough contiguous physical memory is not available to perform the BIOS > > update running under > > this Operating System. Reboot and try again. > > > > R610_BIOS_C6MRW_LN_6.4.0 could not be installed > > > > Done! Please run 'dsu --inventory' to check the inventory > > > > > > > > _______________________________________________ > > Linux-PowerEdge mailing list > > Linux-PowerEdge@dell.com<mailto:Linux-PowerEdge@dell.com> > > https://lists.us.dell.com/mailman/listinfo/linux-poweredge > > > > > > > > _______________________________________________ > > Linux-PowerEdge mailing list > > Linux-PowerEdge@dell.com<mailto:Linux-PowerEdge@dell.com> > > https://lists.us.dell.com/mailman/listinfo/linux-poweredge > > _______________________________________________ Linux-PowerEdge mailing list Linux-PowerEdge@dell.com https://lists.us.dell.com/mailman/listinfo/linux-poweredge